The store will not work correctly when cookies are disabled.
SPSY100 Single Point Load Cell
Load cells for off centre loads, suitable for building CE-M approved scales with a single load cell for platforms up to 500 x 400 mm.
- C3 precision class
- Off center load compensated
- Made in 17-4 PH stainless steel
- IP68/IP69K protection
- Max. capacity: 100kg
- For platforms with dimensions up to 500 x 400 mm
- Shielded connection cable
- Test certificate available upon request
- Minimum load cell verification interval: Vmin = EMax / 10.000
- Maximum number of verification intervals: nLC = 3000
- Full Scale Output: 2mV/V +/- 10%
- Temperature effect on zero:
- Temperature effect on full scale output:
- ±0,0117% F.S./10K (-10°C/+20°C)
- ±0,0175% F.S./10K (+20°C/+40°C)
- Compensated Temperature Range: -10°C/+40°C
- Operating Temperature Range: -10°C/+50°C
- Creep at nominal load in 30 minutes: ± 0,01% F.S.
- Maximum tolerated excitation voltage: 15 VDC
- Input Resistance: 380 ± 15 Ohm
- Output Resistance: 350 ± 10 Ohm
- Insulation Resistance (100V) >2000 MOhm
- Safe Overload: 150% F.S.
- Ultimate Overload: 300% F.S.
- Nominal displacement: < 0.5 mm
- 6-wire shielded cable, 3m long, 5mm diameter
More Information| Cable Length | 3m |
|---|
| IP Rating | IP69K |
|---|